Replacement Heat Exchangers

Heat Exchangers

Replace it Right. Leave it Better.

  • ✓ Shell & tube and U-tube HXs, including double wall construction

  • ✓ Tube bundle replacements

    ✓ Shell & coil heat exchangers

    ✓ Plate & frame and brazed plate & frame heat exchangers

    ✓ Packaged Heat Exchanger Skids: Watson McDaniel Heat Miser® and Heli-Flow®, plus Thermo-Pack®, Cooney Technologies' own engineered upgrade

Already know what you need?

Tube Bundle Replacement | Thermo-Pack® Skid System

On-site Measurements · Quick-Ship Options · Drop-In Fits

Heat exchanger Types

Shell & Tube, Shell & Coil, Plate & Frame, and Packaged Systems

Every mechanical room is different. The right match is the one you stop thinking about the day it's installed. Cooney has heat exchangers across every major configuration.

Direct replacements for

Patterson-Kelley Thrush American Standard Taco CEMLine Bell and Gossett and more

Whatever configuration your facility needs, we can engineer a heat exchanger that matches your original.

Shell & Tube / U-Tube

The industry standard, and the safe choice when an exact match matters most. Includes double wall construction.

Get a Quote >

Plate & Frame

Gasketed metal plates in a compact footprint. A Cooney site visit can assess a gasket rebuild versus full replacement.

Get a Quote >

Tube Bundle Replacement

Cooney measures your existing shell and fabricates a duplicate bundle to match, in single- or double-wall construction.

Learn More >

Brazed Plate & Frame

No gasket, no gasket failure. The plates fuse into a single sealed core, available in single or double wall construction.

Get a Quote >

Thermo-Pack engineered steam heat exchanger by Cooney Technologies

Packaged Heat Exchangers

Thermo-Pack®: Cooney Technologies' own engineered system, Watson McDaniel Heat Miser® and Heli-Flow® skids. For steam-to-water and water-to-water applications. Fully skidded and pre-engineered, with warranty and parts through one vendor.

Shell & Coil

A single continuous coiled tube instead of a tube bundle and tube sheet: fewer joints, less to leak and a smaller footprint.

Get a Quote >

Start with a site visit

We Go to the Mechanical Room, Not Just the Catalog.

Cooney Technologies' field team documents what's installed, checks access and connection points, and gathers what engineering needs to select the right replacement, whether that's a u-tube, shell and coil, plate and frame, or packaged system.

01

Show Us the Problem

Leaks, capacity issues, failed gaskets, damaged bundles or an aging system.

02

We Measure and Assess

Equipment dimensions, piping connections, clearances and field conditions.

03

Get a Defined Replacement Path

A quote and recommendation grounded in what is actually on site.

Schedule a Site Visit

During the initial visit we take measurements, learn about your complete system, diagnose the challenge, and recommend a solution. No cost, no obligation.

Get Your Heat Exchanger Project Started

Whether you’re matching a failing tube bundle or ready to move to Thermo-Pack®, a Cooney sales rep can measure your system and recommend the right path, no obligation.

Call (610) 783-1136  |  Email sales@cooneytechnologies.com

Frequently Asked Questions

How do I know if I need a new tube bundle or a whole new heat exchanger?

In most cases, the shell outlasts the bundle inside it. A Cooney site visit measures the existing shell and tells you whether a bundle replacement is enough or whether the unit itself needs to be replaced.

What’s the difference between a plate & frame and a shell & coil heat exchanger?

​A plate & frame unit stacks gasketed plates and is compact but relies on gaskets that wear under steam service. A shell & coil unit uses a single continuous coiled tube instead of a tube bundle and tube sheet, with fewer joints and less to leak. Watson McDaniel's Heat Miser® is designed around a plate & frame core; the Heli-Flow® is a shell & tube design with baffles, and Thermo-Pack® is a shell & coil design.

What is a double wall heat exchanger, and do I need one?

A double wall heat exchanger has two physical barriers between the fluids, so a leak vents to atmosphere instead of mixing the fluids. It's typically required for potable water, food & beverage, and process applications.

Can Cooney supply a replacement unit or components for my existing AIC or Watson McDaniel heat exchanger?

Yes. Cooney supplies heat exchangers across the AIC line and is a stocking Watson McDaniel distributor, including Heat Miser® and Heli-Flow® components. A site visit confirms model and configuration before anything is quoted.

Do you have tube bundles for other manufacturers’ shells?

Yes. Cooney supplies replacement tube bundles engineered to fit shells from Patterson-Kelley, Thrush, American Standard, Taco, CEMLine, Bell & Gossett, and other major manufacturers, in straight tube or U-tube, single or double wall.

How long does a replacement take?

Lead time depends on the equipment, configuration and materials. Tube bundle replacements typically run 1–2 weeks, while complete heat exchanger lead times can vary significantly. A basic unit may take 7–8 weeks. An early site visit helps confirm what is needed and keeps the replacement process moving before the existing unit fails completely.

What is Thermo-Pack® and how is it different from what I have now?

Thermo-Pack® is Cooney’s engineered shell-and-coil steam-to-water heat exchanger system. Unlike a conventional shell-and-tube unit, it uses fully welded 316L stainless steel coils, so there is no removable tube bundle to maintain or replace. Its cross-counterflow design delivers 10–15% greater efficiency than a standard shell-and-tube unit, and the heat exchanger is backed by a five-year warranty.

Do you offer site visits?

Yes, at no cost. A Cooney Technologies Sales Consultant measures your existing equipment on site and recommends the right replacement or upgrade path.